Sign In | Join Free | My himfr.com
Home > CAT6 Lan Cable >

Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper

    Buy cheap Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper from wholesalers
     
    Buy cheap Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper from wholesalers
    • Buy cheap Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper from wholesalers
    • Buy cheap Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper from wholesalers

    Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper

    Ask Lasest Price
    Brand Name : Aitong
    Model Number : cat-6e-UTP
    Certification : ISO9001
    Price : As required
    Payment Terms : L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 200 winding box day
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper

    305m UTP Bare copper Network Cable Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable


    Product description


    CAT6 Premium Line patch cables are ready for your high speed network up to Gigabit Ethernet. Our CAT6 patch cables all meet or exceed industry standards and European regulations. We have Cat6 Ethernet patch cables of many different lengths and colors. Since CAT6 Ethernet components are backward-compatible with older network equipment (including CAT3, CAT5 and CAT5e), CAT6 patch cables and cords integrate legacy components such as printers and computers.


    Construction

    • Cat6 UTP Twisted Pair Cable
    • Pass Test High Performance Computer Networking Cable
    • Suitable for Fast, Gigabit, and 10-Gigabit Ethernet
    • Digital Communication Applications of up to 550MHz Bandwidth
    • Exceeds ANSI/TIA 568-D.2 , ISO/IEC 11801 Standards
    • Tangle Free Reelex and Colorful Easy Pull Box Packing with No Extra Charge
    • CE / ISO / RoHS Approved, PVC Jacket Use Indoors
    • ETL CMX / CM / CMG / CMR / CMP Rated Are Available​

    Appliacation

    • CAT6 cabling supports 10GBASE-T 10 Gigabit Ethernet application standard, but the transmission distance is limited to no more than 37m (and external crosstalk test needs to be added to re evaluate the anti external electromagnetic interference performance of category 6 Cabling System). Cat6a cabling can support 10GBASE-T Ethernet application standard and meet standard applications within 100m without additional external crosstalk test.
    • Cat6a cabling system can fully meet the application requirements of 10 Gigabit Ethernet at a distance of 100 meters. Cat6a cabling system has many defects in transmitting 10 Gigabit Ethernet.

    ▌Parameter


    Environmental Space:Indoor
    Suitable Applications:Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T, 10 Base - T, FDDI, ATM

    Physical Characteristics (Overall)

    Conductor


    ElementAWGStrandingMaterialNo. of Pairs
    Individual pair23SolidBC - Bare Copper4
    Conductor Count:8
    Total Number of Pairs:4
    Conductor Size:23 AWG

    Insulation


    ElementTypeMaterialNominal Diameter
    Individual pairDielectricPolyethylene0.96 mm
    Bonded-Pair:No

    Color Chart


    NumberColor
    Pair 1White/Blue & Blue
    Pair 2White/Orange & Orange
    Pair 3White/Green & Green
    Pair 4White/Brown & Brown

    Outer Jacket Material


    MaterialColorNominal DiameterDiameter +/- Tolerance
    PVC - Polyvinyl ChlorideGrey or Blue5.4 mm0.3 mm

    Construction and Dimensions


    Min Elongation at Breakof Conductors:10 %
    Min Elongation at Breakof Insulation:100 %

    Cabling


    DescriptionFiller
    4 pairs twisted togetherCross Web of Polyolefin
    Min Elongation at Breakof Jacket:100 %
    Min Tensile Strength of Jacket:9 MPa

    Electrical Characteristics


    Conductor DCR


    Max. Conductor DCRMax DCR Unbalanced Between Pairs [%]Max. DCR Unbalanced Within Pair [%]
    95 Ohm/km4 %2 Ohm

    Capacitance


    Max. Capacitance UnbalanceMax. Mutual Capacitance
    1,600 pF/m56 pF/m

    Impedance


    Nominal Characteristic Impedance100Ohm

    Delay


    Max. Delay SkewNominal Velocity of Propagation (VP) [%]
    40 ns/100m70 %

    High Freq


    Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Min. TCL [dB]Min. ELTCTL [dB]
    1 MHz2.1 dB/100m75.3 dB72.3 dB73.2 dB70.2 dB70 dB67 dB20 dB40 dB35 dB
    4 MHz3.8 dB/100m66.3 dB63.3 dB62.4 dB59.4 dB58 dB55 dB23 dB34 dB23 dB
    10 MHz6 dB/100m60.3 dB57.3 dB54.3 dB51.3 dB50 dB47 dB25 dB30 dB15 dB
    16 MHz7.6 dB/100m57.2 dB54.2 dB49.6 dB46.6 dB45.9 dB42.9 dB25 dB28 dB10.9 dB
    20 MHz8.5 dB/100m55.8 dB52.8 dB47.3 dB44.3 dB44 dB41 dB25 dB27 dB9 dB
    31.2 MHz10.7 dB/100m52.9 dB49.9 dB42.1 dB39.1 dB40.1 dB37.1 dB23.6 dB25.1 dB5.1 dB
    62.5 MHz15.5 dB/100m48.4 dB45.4 dB32.9 dB29.9 dB34.1 dB31.1 dB21.5 dB22 dB
    100 MHz19.9 dB/100m45.3 dB42.3 dB25.4 dB22.4 dB30 dB27 dB20.1 dB20 dB
    155 MHz25.3 dB/100m42.4 dB39.4 dB17.1 dB14.1 dB26.2 dB23.2 dB18.8 dB18.1 dB
    200 MHz29.1 dB/100m40.8 dB37.8 dB11.6 dB8.6 dB24 dB21 dB18 dB17 dB
    250 MHz33 dB/100m39.3 dB36.3 dB6.3 dB3.3 dB22 dB19 dB17.3 dB16 dB

    High Freq Table Note:): Limits below 4MHz are for information only.
    Coupling Attenuation Class:Type III
    Segregation class according EN50174-2:a

    Current


    Max. Recommended Current [A]1.5A

    Voltage


    Voltage Rating [V]72V

    Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper

    Temperature Range


    Installation Temp Range:0°C To +50°C
    Operating Temp Range:-30°C to +60°C

    Mechanical Characteristics


    Bulk Cable Weight:37 kg/km
    Max Recommended Pulling Tension:80 N
    Min Bend Radius During Installation:46 mm
    Min Bend Radius During Operation:23 mm

    Standards


    ISO/IEC Compliance:ISO/IEC 11801 2nd edition (2002) and ISO/IEC 11801 Amendment 2 (2010)
    CPR Euroclass:Eca
    CENELEC Compliance:EN 50173-1 (2011)
    Data Category:Category 6
    ANSI Compliance:ANSI/TIA/EIA 568-C.2 (2009)

    ▌Flammability, LS0H, Toxicity Testing


    ISO/IEC Flammability:IEC 60332-1
    Burning Load:460 kJ/m

    ▌Part Number

    Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper

    Variants


    Item #Color
    7965E.05A305Black
    7965E.011000Blue
    7965E.01200Blue
    7965E.01305Blue
    7965E.01500Blue
    7965E.01A305Blue
    7965E.01B100Blue
    7965E.001000Gray, RAL 7032
    7965E.00305Gray, RAL 7032
    7965E.00500Gray, RAL 7032
    7965E.00A305Gray, RAL 7032
    7965E.00B100Gray, RAL 7032
    7965E.03500Green
    7965E.03305Green

    Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare CopperIndoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper

    Panking


     Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare CopperCable weightGross weight
    9.3kg10kg
    Box size (CM)Specifications
    21.5×35×35305m/box

    Application scenario


    Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare CopperIndoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare CopperIndoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare CopperIndoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper
    Network TVDesktop computerNotebook computerPrinter
    Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare CopperIndoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare CopperIndoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare CopperIndoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper
    RouterSet top boxCabinetCamera

    Frequently asked question (FAQ)

    Q: Are you a cable and wire manufacturer?
    — Yes, we are a professional wire and cable manufacturer.

    Q: Can you offer a discount on cables?
    — The price is negotiable according to the specification and quantity.

    Q: Can you offer FREE samples?
    — Yes,FREE samples are available, you just take care of the freight fee.

    Q: What about your MOQ?
    — Usually, our MOQ is 5000 Meters, but we’ d love to talk about your MOQ.

    Q: Do you accept customize cables?
    — Yes, we are more than happy to make OEM and ODM for you.

    Q: How long is the lead time?
    — Usually it’s about 10-14 days.


    Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper

    Quality Indoor Fluk E Pass 4pr 23 Awg Cat6 Lan Cable 305m UTP Bare Copper for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sichuan Aitong Wire & Cable, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)